MTE RL Line/Load Reactors

MTE RL Line/Load Reactors

Ultimate Power Quality Solutions
MTE’s RL Line/Load Reactors stand as the epitome of power quality solutions, boasting a long-standing history of proven performance. Designed to be rugged and robust, these reactors are unmatched in their ability to absorb power line disturbances that can potentially damage or shut down variable frequency drives (VFDs) and other sensitive equipment. Whether on the line side or load side, RL Line/Load Reactors offer an effective solution to reduce nuisance tripping, minimize harmonic distortion, and mitigate long lead effects.

Contact us today to learn more about how MTE RL Line/Load Reactors can benefit your specific applications and to find the perfect reactor for your needs.

Key Features:

Robust Design: Engineered for superior filtering of power line disturbances, ensuring long-term reliability and durability.
No Derating Required: Harmonic compensated and protected to assure optimal performance in the presence of harmonics.
Wide Range of Impedance Options: Available in 1.5%, 3%, and 5% impedance levels to meet various application needs.
Comprehensive Current Range: Supports a full line of currents from 1A to 1,500A.
Continuous Service Factor: Reactors rated from 1 to 750 Amps are designed with a 150% continuous service factor, while those rated above 750 Amps have a 125% continuous service factor.
High Overload Rating: Capable of handling 200% of the rated current for 30 minutes and 300% of the rated current for 1 minute.
Noise Reduction: Constructed to significantly reduce audible noise, enhancing the working environment.
Multiple Cabinet Designs: Available in configurations that meet NEMA 1/2 and 3R standards, providing flexibility in installation.

Benefits:

Enhanced Power Quality: Delivers improved power quality by effectively reducing harmonic distortion and power line disturbances.
Increased Productivity: Reduces nuisance tripping and equipment shutdowns, leading to more consistent and reliable operations.
Complete Peace of Mind: Robust construction and high performance provide reliability and confidence in the system’s operation.
Versatile Application: Suitable for virtually any 4 or 6-pulse rectifier or power conversion unit, ensuring broad applicability.

Specifications:

Impedance Levels: 1.5%, 3%, and 5%
Continuous Service Factor:
Reactors rated 1 to 750 Amps – 150% of rating
Reactors rated above 750 Amps – 125% of rating
Overload Rating:
200% of rated current for 30 minutes
300% of rated current for 1 minute
Input Voltage Range: 208V – 690V
Current Range: 1A – 1,500A

Typical Applications:

Variable Frequency Drives (VFDs): Ensures the reliable and efficient operation of VFDs by mitigating power line disturbances.
Sensitive Equipment: Protects sensitive equipment from power quality issues that can cause damage or shutdowns.
4 or 6-Pulse Rectifiers: Provides robust filtering solutions for rectifiers, enhancing their performance and longevity.
Power Conversion Units: Suitable for a variety of power conversion applications, ensuring stable and efficient operation.

Why Choose MTE RL Line/Load Reactors?

Choosing MTE RL Line/Load Reactors means investing in a reliable and proven solution for power quality. With their robust design, high overload capacity, and wide range of applications, these reactors ensure that your equipment runs smoothly and efficiently, minimizing downtime and maintenance costs. Enhance your power quality, boost productivity, and achieve peace of mind with MTE’s RL Line/Load Reactors.

Line/Load Selection Table – 1/.75-10/7.5 HP/kw
208-690 Volts, 50/60 hz (Open Type)
RatingsHP/kw1/.751.5/1.12/1.53/2.25/3.77.5/5.510/7.5
400 Volts3% ImpedanceRL-00403RL-00402RL-00402RL-00803RL-00802RL-01202RL-01802
50/60 HZ
400 Volts5% ImpedanceRL-00202RL-00404RL-00403RL-00804RL-00803RL-01203RL-01803
50/60 HZ
690 Volts2% Impedance   RL-00403RL-00402RL-00801RL-01202
50/60 HZ   
690 Volts3% Impedance   RL-00402RL-00404RL-00804RL-01203
50/60 HZ   
Line/Load Selection Table – 15/11-100/75 HP/kw
208-690 Volts, 50/60 hz (Open Type)
RatingsHP/kw15/1120/1525/18.530/2240/3050/37.560/4575/55100/75
400 Volts 50/60 HZ3% ImpedanceRL-2502RL-3502RL-4502RL-4502RL-8002RL-8002RL-10002RL-13002RL-16002
400 Volts 50/60 HZ5% ImpedanceRL-2503RL-3503RL-4503RL-5503RL-8003RL-10003RL-10003RL-13003RL-16003
690 Volts 50/60 HZ2% ImpedanceRL-1202RL-1802RL-2502RL-2502RL-3502RL-4502RL-5502RL-5502RL-8002
690 Volts 50/60 HZ3% ImpedanceRL-1203RL-1803RL-2503RL-2503RL-3503RL-4503RL-4502RL-5503RL-8003
Line/Load Selection Table – 125/93 750/550 HP/kw
208-690 Volts, 50/60 hz (Open Type)
RatingsHP/kw125/93150/112200/150250/187300/225350/262400/300500/375600/450700/550
480 Volts 50/60 HZ3% ImpedanceRL-16002RL-20002B14RL-25002B14RL-32002B14RL-40002B14RL-50002RL-50002RL-60002RL-75002RL-85002B14
480 Volts 50/60 HZ5% ImpedanceRL-16003RL-20003B14RL-25003B14RL-32003B14RL-40003B14RL-50003RL-50003RL-60003RL-75003RL-85003B14
690 Volts 50/60 HZ2% ImpedanceRL-10002RL-13002RL-16002RL-20002B14RL-25002B14RL-25002B14RL-32002B14RL-40002B14RL-40002B14RL-50002
690 Volts 50/60 HZ3% ImpedanceRL-10003RL-13003RL-16003RL-20003B1425003B14RL-25003B14RL-32003B14RL-40003B14RL-50003RL-50003