<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Inverters - Westek Electronics</title>
	<atom:link href="https://westek.com.au/category/products/parent-testing-and-measurement-equipment/child-testing-and-measurement-equipment-inverters/feed/" rel="self" type="application/rss+xml" />
	<link>https://westek.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 09 Feb 2025 00:06:20 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://westek.com.au/wp-content/uploads/2026/05/cropped-Westek-Favicon-32x32.webp</url>
	<title>Inverters - Westek Electronics</title>
	<link>https://westek.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Inverter Modules</title>
		<link>https://westek.com.au/inverter-modules/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 09 Feb 2025 00:03:38 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Inverters]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=2067</guid>

					<description><![CDATA[<h4>Type WR-5073</h4>
<p>The post <a href="https://westek.com.au/inverter-modules/">Inverter Modules</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features</h5>



<p class="wp-block-paragraph"><strong>Switched-Mode Technology: </strong>The WR-5073 utilizes advanced switched-mode technology, ensuring efficient power conversion and reliable operation.<br><strong>High Efficiency: </strong>Designed for energy savings, this inverter achieves efficiency levels ranging between 81% and 91%, minimizing energy losses.<br><strong>Good Regulation Dynamics: </strong>The inverter offers excellent control and response times, maintaining stable output under varying load conditions.<br><strong>High Short-Circuit Current: </strong>Capable of delivering a high short-circuit current, the WR-5073 ensures robust performance even during fault conditions.<br><strong>Short-Circuit Protection: </strong>The inverter is designed to be short-circuit proof, providing enhanced safety and reliability.<br><strong>Compact Design: </strong>With its compact form factor, the WR-5073 is ideal for installations where space is limited.<br><strong>Lightweight: </strong>The lightweight design facilitates easy handling and installation.<br><strong>Deep Discharge Protection: </strong>The inverter includes deep discharge protection to extend the lifespan of connected batteries.<br><strong>Electronic Bypass: </strong>An integrated electronic bypass allows for seamless switching between the inverter and mains power without interruption.<br><strong>N or N+1 Operation (Optional):</strong> The inverter supports both standard and N+1 redundant operation, enhancing system reliability.<br><strong>Battery Filter: </strong>Equipped with a battery filter, the inverter ensures clean and stable DC input power.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Technical Specifications</h5>



<p class="wp-block-paragraph"><strong>Rated Power (VA): </strong>Available in 1000, 1500, 2000, and 3000 VA models<br><strong>DC Input Voltage:</strong><br>24 V: 1000 VA<br>48 V: 1500 VA<br>60 V: 2000 VA<br>110 V: 3000 VA<br>220 V: 3000 VA<br><strong>Input Voltage Range: </strong>-15% to +20% (for &lt;48 V, -10% to +20%)<br><strong>Output AC Voltage: </strong>230 V ± 1%<br><strong>Output Frequency: </strong>Available in 25 Hz, 100 Hz, or 50 Hz ± 0.1%<br><strong>Total Harmonic Distortion (THD): </strong>&lt;3% (with linear load)<br><strong>Power Factor: </strong>0.3 inductive to 0.8 capacitive; power reduction when deviating from cos φ = 0.8 inductive<br><strong>Efficiency: </strong>81% to 91%<br><strong>Overload Capability:</strong><br>125% for 10 minutes<br>110% for 20 minutes<br><strong>Short Circuit Behavior:</strong><br>Short-circuit proof, with a short-circuit current of 3x I_N for 20 milliseconds, followed by 2x I_N for 5 seconds<br><strong>Noise Level: </strong>&lt; 55 dB(A)<br><strong>EMC Compliance: </strong>EN 61000-6-2, EN 61000-6-4<br><strong>Test Voltages:</strong><br><strong>Input to Output: </strong>3.75 kV AC<br><strong>Input/Output to Ground: </strong>2 kV AC<br><strong>Cooling Type:</strong><br>“AF” for forced air cooling<br>“AN” for natural air cooling<br><strong>Permissible Installation Height: </strong>1000 meters above sea level at rated load<br><strong>Environmental Conditions:</strong><br><strong>Operation: </strong>3K3 according to EN 60721-3-3<br><strong>Operating Temperature: </strong>-5°C to +40°C<br><strong>Dimensions: </strong>As per the datasheet<br><strong>Protection Class:</strong> IP20, according to EN 60529</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Execution and Operation</h5>



<p class="wp-block-paragraph"><strong>Design:</strong><br>19-inch rack-mount or partial rack-mount for easy installation<br>Front-mounted input/output terminals<br>Front panel on/off switch for the inverter<br><strong>Operating mode selector:</strong><br>Continuous operation<br>Standby operation<br>Startup operation<br><strong>Signaling (LED indicators on the front panel):</strong><br>Consumer voltage OK<br>DC voltage OK<br>Load on inverter<br>Load on mains<br>Inverter fault<br>Phase position OK<br>Operation</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Functionality</h5>



<p class="wp-block-paragraph"><strong>PWM Technology: </strong>The inverter operates using PWM technology with state-of-the-art power transistors for efficient power conversion.<br><strong>Galvanic Isolation: </strong>The input and output are galvanically isolated, ensuring safe and interference-free operation.<br><strong>Uninterruptible Electronic Bypass: </strong>An electronic bypass is integrated, enabling seamless transition between the inverter and mains power during maintenance or faults.<br><strong>Remote Signaling (2 potential-free contacts):</strong><br>Inverter fault<br>Inverter operation</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Protection and Monitoring Features</h5>



<p class="wp-block-paragraph"><strong>Overload and Short-Circuit Protection: </strong>The inverter is equipped with robust protection mechanisms to handle overloads and short circuits effectively.<br><strong>Input Under-Voltage Protection: </strong>The inverter monitors the input voltage and provides protection against under-voltage conditions.<br><strong>Output Over-/Under-Voltage Protection: </strong>Both over-voltage and under-voltage conditions on the output are monitored and controlled.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Optional Features</h5>



<p class="wp-block-paragraph"><strong>External Remote Signaling: </strong>Additional remote signaling options can be provided for external monitoring.<br><strong>Special Frequencies: </strong>The inverter can be configured to operate at special frequencies to meet specific application requirements.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<p class="wp-block-paragraph">This static inverter, WR-5073, is designed for high performance and reliability, making it suitable for a wide range of industrial and critical applications. Its advanced features and robust construction ensure continuous and stable power supply, even under demanding conditions.</p><p>The post <a href="https://westek.com.au/inverter-modules/">Inverter Modules</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Static Inverters</title>
		<link>https://westek.com.au/static-inverters/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sat, 08 Feb 2025 23:56:57 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Inverters]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=2064</guid>

					<description><![CDATA[<p>Our static inverters, including types WR-5080 (1~), WR-5081 (3~), and WR-5073 (inverter plug-in modules), are engineered to provide uninterruptible power supply (UPS) solutions across a variety of critical applications. These inverters are designed to bridge short-term interruptions, power failures, voltage fluctuations, and other power disturbances, making them ideal for use in sectors such as data processing, automation, and control systems. They are particularly effective in environments like railways, industrial plants, power stations, telecommunications, air traffic control, and hospitals, where reliability and quality are paramount.</p>
<p>The post <a href="https://westek.com.au/static-inverters/">Static Inverters</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features</h5>



<p class="wp-block-paragraph"><strong>Advanced Transistor Inverter Technology: </strong>The WR-5080 and WR-5081 inverters utilize transistor inverters with PWM (Pulse Width Modulation) technology, ensuring efficient and precise power conversion. The incorporation of an isolation transformer in the inverter output enhances the quality and safety of the power delivered to the load.<br><strong>Electronic and Manual Bypass: </strong>Both electronic and hand-operated bypass options are integrated into the system, allowing seamless transitions between inverter and bypass modes during maintenance or faults, ensuring uninterrupted power delivery.<br><strong>User-Friendly Interface: </strong>A color TFT touchscreen display provides an intuitive interface for easy monitoring and control of the inverter&#8217;s operation. The clear display simplifies the management of system parameters and enhances user experience.<br><strong>High Power Availability: </strong>The WR-5080 supports single-phase systems up to 200 kVA, while the WR-5081 supports three-phase systems up to 500 kVA. This scalability ensures that the inverters can meet a wide range of power requirements.<br><strong>Parallel Operation Capability: </strong>Up to eight inverter units can be connected in parallel, allowing the system to scale up to a total of 1500 kVA. This feature provides flexibility in designing larger power systems while maintaining high availability.<br><strong>Two-Stage Fan Monitoring: </strong>The power units are equipped with two-stage fan monitoring (warning and shutdown) to ensure the longevity and reliability of the inverters by preventing overheating.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Customization Options</h5>



<p class="wp-block-paragraph"><strong>Input Voltage Flexibility: </strong>Available input voltage options include 24, 48, 60, 110, 220, and 372 V DC, with the possibility of configurations up to 1000 V for specific applications.<br><strong>Isolating Transformer Compliance: </strong>The inverters can be equipped with isolating transformers that meet VDE 0558-507 or ÖVE/ÖNORM E 8007 standards for bypass cabinets.<br><strong>Parallel Operation Support: </strong>Parallel running devices can be integrated, enabling the creation of highly scalable and redundant power systems.<br><strong>Interface Variety: </strong>A wide range of communication interfaces are available, including SNMP, Modbus, and other industry-standard protocols, to facilitate easy integration into existing infrastructure.<br><strong>Enhanced Cabinet Configurations: </strong>Cabinets can be customized with options such as interior lighting, heating, sealed cable entry, and protection classes higher than IP20, ensuring that the inverters can operate in a variety of challenging environments.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Technical Specifications</h5>



<p class="wp-block-paragraph"><strong>Rated Power:</strong><br><strong>WR-5080: </strong>5-200 kVA (1~)<br><strong>WR-5081: </strong>5-500 kVA (3~)<br><strong>Execution: </strong>Transistor, PWM, galvanically isolated<br><strong>DC Input Voltage: </strong>24, 48, 60, 110, 120, 220, up to 1000 V possible<br><strong>AC Input Voltage (Bypass):</strong><br>1/N/PE AC 230 V<br>3/N/PE AC 400/230 V<br>AC Input Voltage Tolerance: ± 10%<br><strong>Frequency: </strong>50 or 60 Hz ± 5%<br><strong>Nominal AC Output (Inverter Output):</strong><br><strong>Voltage: </strong>1/N/PE AC 230 V or 3/N/PE AC 400/230 V<br><strong>Frequency: </strong>50Hz ± 5%<br><strong>Overload Capability:</strong><br>10 x I_N for 10 ms<br>1.50 x I_N for 60 seconds<br>1.25 x I_N for 10 minutes<br>1.10 x I_N for 20 minutes<br><strong>Short Circuit Behavior:</strong><br>Short-circuit proof, with a short-circuit current of 2x I_N (1-phase) and 2-4x I_N (3-phase)<br>Inverter stop after 5 seconds<br><strong>Permissible Power Factor: </strong>0.0 inductive to 0.0 capacitive (Power reduction when deviating from cos φ 0.8 ind.)<br><strong>Permissible Crest Factor: </strong>≤ 2.3 at rated power<br><strong>Output Voltage Adjustment Range: </strong>± 5% (with a restriction of nominal data at +5%)<br><strong>Settling Time: </strong>&lt; 4 ms (instantaneous value control)<br><strong>Waveform: </strong>Sinusoidal with a distortion factor of ≤ 3% under linear load<br><strong>Synchronization Range: </strong>50Hz ± 3%<br><strong>Frequency Change Rate: </strong>1Hz/s</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Environmental and Safety Standards</h5>



<p class="wp-block-paragraph"><strong>Protection Class (EN 61140): </strong>I<br><strong>Protective Conductor Current: </strong>&lt; 5% I_N, typically 50 mA<br><strong>Protection Class (EN 60529): </strong>IP 20 (floor IP00)<br><strong>Permissible Installation Height: </strong>1,000 m above sea level, with a minimum air pressure of 870 hPa<br><strong>Painting: </strong>RAL 7035, solid textured paint<br><strong>Cooling Type: </strong>Natural cooling (“ON”) or forced air cooling (“AF”)<br><strong>Relay Interface: </strong>8 signals with 2 potential-free changeover contacts per signal, covering:<br>Inverter operation<br>Network operation<br>Battery discharge<br>Advance warning of deep discharge<br>Network failure<br>System malfunction<br>2x Reserve<br><strong>Environmental Conditions:</strong><br><strong>Storage: </strong>EN 60721-3-1, 1K21 / 1M11, +5 to +40 °C<br><strong>Transport: </strong>EN 60721-3-2, 2K12 / 2M4, -45 to +70 °C<br><strong>Operation: </strong>EN 60721-3-3, 3K22 / 3M11, +5 to +40 °C, 5-85% relative humidity, no condensation, Pollution level 2</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Compliance and Standards</h5>



<p class="wp-block-paragraph"><strong>EMC Directive: </strong>2014/30/EU<br><strong>RoHS Directive: </strong>2011/65/EU<br><strong>EMC Standards: </strong>EN61439-1, EN61439-2, EN 62040-2</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<p class="wp-block-paragraph">These static inverters provide a reliable and versatile solution for maintaining power continuity across various critical applications. Their modularity, scalability, and customization options make them adaptable to a wide range of environments and power requirements.</p><p>The post <a href="https://westek.com.au/static-inverters/">Static Inverters</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
