<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hipot testers - Westek Electronics</title>
	<atom:link href="https://westek.com.au/category/products/parent-testing-and-measurement-equipment/child-testing-and-measurement-equipment-hipot-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://westek.com.au</link>
	<description></description>
	<lastBuildDate>Tue, 25 Feb 2025 05:24:12 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://westek.com.au/wp-content/uploads/2026/05/cropped-Westek-Favicon-32x32.webp</url>
	<title>Hipot testers - Westek Electronics</title>
	<link>https://westek.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Vitrek 95X Series Hipot Testers</title>
		<link>https://westek.com.au/vitrek-95x-series-hipot-testers/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 08 Dec 2024 05:57:24 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Hipot testers]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=562</guid>

					<description><![CDATA[<p>The Vitrek 95X Series represents the pinnacle of high-performance Hipot Testers. Designed to meet the most stringent requirements of electrical and electronic equipment manufacturing, these analyzers offer advanced capabilities, flexibility, and reliability for AC and DC Hipot testing, insulation resistance (IR) measurements, ground bond testing, and four-wire ohmmeter functionality.</p>
<p>For more information on each model and to find the right tester for your application, contact us for a quote at info@westek.com.au.</p>
<p>The post <a href="https://westek.com.au/vitrek-95x-series-hipot-testers/">Vitrek 95X Series Hipot Testers</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features:</h5>



<div class="wp-block-group"><div class="wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained">
<p class="wp-block-paragraph"><strong>High Voltage Testing:</strong> Perform both AC and DC Hipot tests with precise control and measurement up to 15KV, depending on the model.<br><strong>Insulation Resistance:</strong> Measure insulation resistance up to 6 teraohms, ensuring safety and compliance.<br><strong>Ground Bond Testing:</strong> Ensure reliable and safe ground connections with up to 40A testing capability.<br><strong>4 Wire Ohmmeter:</strong> Accurate low resistance measurements using four-wire Kelvin connections for precise results.<br><strong>User-Friendly Interface:</strong> Easy to use with a clear, intuitive interface and automation options for efficient testing.</p>
</div></div>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Model Descriptions:</h5>



<div class="wp-block-group"><div class="wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained">
<p class="wp-block-paragraph"><strong>951i:</strong> 6KV AC/DC/IR/LR Electrical Safety Compliance Analyzer<br><strong>952i: </strong>6KV AC/DC/IR/GB/LR Electrical Safety Compliance Analyzer<br><strong>953i:</strong> 11KVDC 6KVAC/IR/LR Electrical Safety Compliance Analyzer<br><strong>954i:</strong> 11KVDC 6KVAC/IR/GB/LR Electrical Safety Compliance Analyzer<br><strong>955i:</strong> 11KVDC 10KVAC/IR/LR Electrical Safety Compliance Analyzer<br><strong>957i:</strong> 15KVDC 6KVAC/IR/LR Electrical Safety Compliance Analyzer<br><strong>959i:</strong> 40A Ground Bond/LR Safety Compliance Analyzer</p>
</div></div>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Model Comparison:</h5>



<figure class="wp-block-table"><table><tbody><tr><td><strong>Capability</strong></td><td class="has-text-align-center" data-align="center"><strong>951i</strong></td><td class="has-text-align-center" data-align="center"><strong>952i</strong></td><td class="has-text-align-center" data-align="center"><strong>953i</strong></td><td class="has-text-align-center" data-align="center"><strong>954i</strong></td><td class="has-text-align-center" data-align="center"><strong>955i</strong></td><td class="has-text-align-center" data-align="center"><strong>957i</strong></td><td class="has-text-align-center" data-align="center"><strong>959i</strong></td></tr><tr><td><strong>AC Hipot</strong></td><td class="has-text-align-center" data-align="center">20V-6KV</td><td class="has-text-align-center" data-align="center">20V-6KV</td><td class="has-text-align-center" data-align="center">20V-6KV</td><td class="has-text-align-center" data-align="center">20V-6KV</td><td class="has-text-align-center" data-align="center">50V-10KV</td><td class="has-text-align-center" data-align="center">20V-6KV</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td>(Max Std Current)</td><td class="has-text-align-center" data-align="center">50mA</td><td class="has-text-align-center" data-align="center">50mA</td><td class="has-text-align-center" data-align="center">50mA</td><td class="has-text-align-center" data-align="center">50mA</td><td class="has-text-align-center" data-align="center">30mA</td><td class="has-text-align-center" data-align="center">50mA</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td>(500VA Option)</td><td class="has-text-align-center" data-align="center">100mA</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">100mA</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">100mA</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td>(2KV Max Option)</td><td class="has-text-align-center" data-align="center">200mA</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">200mA</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">200mA</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td>(30KVAC Ext. opt)</td><td class="has-text-align-center" data-align="center">10mA</td><td class="has-text-align-center" data-align="center">10mA</td><td class="has-text-align-center" data-align="center">10mA</td><td class="has-text-align-center" data-align="center">10mA</td><td class="has-text-align-center" data-align="center">10mA</td><td class="has-text-align-center" data-align="center">10mA</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td><strong>DC Hipot / IR</strong></td><td class="has-text-align-center" data-align="center">50V-11KV</td><td class="has-text-align-center" data-align="center">50V-11KV</td><td class="has-text-align-center" data-align="center">50V-11KV</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">75-15KV</td><td class="has-text-align-center" data-align="center">10mA</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td>(Max Current)</td><td class="has-text-align-center" data-align="center">50mA</td><td class="has-text-align-center" data-align="center">50mA</td><td class="has-text-align-center" data-align="center">30mA</td><td class="has-text-align-center" data-align="center">30mA</td><td class="has-text-align-center" data-align="center">30mA</td><td class="has-text-align-center" data-align="center">30mA</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td>(MAX IR)</td><td class="has-text-align-center" data-align="center">2T</td><td class="has-text-align-center" data-align="center">2T</td><td class="has-text-align-center" data-align="center">4T</td><td class="has-text-align-center" data-align="center">4T</td><td class="has-text-align-center" data-align="center">4T</td><td class="has-text-align-center" data-align="center">6T</td><td class="has-text-align-center" data-align="center">—</td></tr><tr><td><strong>40A Ground Bond</strong></td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">—</td><td class="has-text-align-center" data-align="center">Yes</td></tr><tr><td><strong>4 Wire Ohmmeter</strong></td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">Yes</td><td class="has-text-align-center" data-align="center">Yes</td></tr></tbody></table></figure>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Typical Applications:</h5>



<div class="wp-block-group"><div class="wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained">
<p class="wp-block-paragraph"><strong>Consumer Electronics:</strong> Ensuring the safety and compliance of household and personal electronic devices.<br><strong>Medical Equipment:</strong> Verifying the safety of medical devices to meet stringent regulatory standards.<br><strong>Automotive Components:</strong> Testing automotive electronics for safety and reliability in harsh environments.<br><strong>Aerospace and Defense:</strong> Ensuring high-voltage components meet rigorous safety and performance standards.<br><strong>Industrial Machinery: </strong>Testing and compliance for heavy-duty industrial equipment and machinery.<br><strong>Power Supplies and Transformers:</strong> Ensuring the safety and reliability of power conversion equipment.<br><strong>Renewable Energy Systems:</strong> Testing components used in solar, wind, and other renewable energy systems.<br><strong>Telecommunications: </strong>Ensuring the safety and compliance of telecom equipment and infrastructure.</p>
</div></div>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Optional Accessories and Add-Ons:</h5>



<div class="wp-block-group"><div class="wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained">
<p class="wp-block-paragraph"><strong>QTPro II-950: </strong>QuickTest Pro II Test Automation Software<br><strong>GPIB-9:</strong> Optional GPIB Interface<br><strong>500VA: </strong>500VA Output Option (951i, 953i &amp; 957i only)<br><strong>AC-2:</strong> 200mA 2 KVAC Max Output Option<br><strong>AC-30: </strong>30KVAC External Option<br><strong>RPOO-95: </strong>Rear Panel Only Output Terminals<br><strong>HSS-1: </strong>High Side Current Measurement (for grounded loads)<br><strong>PMT-1: </strong>Pulse Mode / High Speed Flash Test Option<br><strong>ISO-CALN-95X: </strong>ISO 17025 Accredited Cal Cert (with purchase)<br><strong>TL-UP1: </strong>Universal Power Receptacle Hipot Test Adaptor<br><strong>TL-UP2: </strong>Universal Power Receptacle Hipot &amp; GB Test Adaptor<br><strong>TL-UP3: </strong>Universal Power Receptacle GB only Test Adaptor<br><strong>TL-IEC1: </strong>IEC 320 C13 Power Socket Hipot Test Lead Set<br><strong>TL-IEC2: </strong>IEC 320 C13 Power Socket Hipot &amp; GB Test Lead Set<br><strong>TL-IEC3: </strong>IEC 320 C13 Power Socket GB only Test Lead Set<br><strong>TL-115-1: </strong>NEMA 5-15 Power Socket Hipot Test Lead Set<br><strong>TL-115-2: </strong>NEMA 5-15 Power Socket Hipot &amp; GB Test Lead Set<br><strong>TL-TP1:</strong> HV Retractable Tip Test Pistol Test Lead 6ft<br><strong>TL-109: </strong>5KV HV Pencil Probe Test Lead Set 4ft<br><strong>TL-209: </strong>Standard HV Alligator Clip Test Lead 4ft<br><strong>TL-30: </strong>Heavy Duty HV Alligator Test Lead Set 4ft<br><strong>K-1: </strong>4-wire Kelvin Low Resistance Measurement Lead Set (10A Max)<br><strong>K-2R: </strong>4-Wire 2 Clip 40A Ground Bond Test Lead Set 4ft<br><strong>RM-1: </strong>Rack Mount Kit<br><strong>RSS-95: </strong>Remote Start Switch<br><strong>RFS-95: </strong>Remote Start Foot Switch<br><strong>USB-1: </strong>USB A to B Cable 6ft (95X/4700 to printer or V7X/PA900 to PC)<br><strong>USB-2: </strong>USB A to RS232 (Serial) Adapter Cable (Requires RS-2)<br><strong>RS-2: </strong>Female to Female Null Modem RS323 (Serial) Cable 6ft<br><strong>GP-1: </strong>1 Meter Shielded GPIB (IEEE-488)</p>
</div></div><p>The post <a href="https://westek.com.au/vitrek-95x-series-hipot-testers/">Vitrek 95X Series Hipot Testers</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Vitrek V7X Series Hipot Testers</title>
		<link>https://westek.com.au/vitrek-v7x-series-hipot-testers/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 08 Dec 2024 03:43:07 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Hipot testers]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=531</guid>

					<description><![CDATA[<h5>Electrical Safety Testing Redefined</h5>
<p>The V7X Series from Vitrek sets a new standard for electrical safety testing with its color touch LCD and high-speed DSP technology. Compact, rugged, and designed to meet tough UL, CSA, TUV, and IEC Hipot requirements, the V7X series offers unbeatable speed, accuracy, user safety, and reliability.</p>
<p>For more information or to request a quote contact us at info@westek.com.au</p>
<p>The post <a href="https://westek.com.au/vitrek-v7x-series-hipot-testers/">Vitrek V7X Series Hipot Testers</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Features and Benefits:</h5>



<p class="wp-block-paragraph"><strong>4.3&#8243; Color Touch Display: </strong>Easy-to-use intuitive user interface.<br><strong>Six Functions: </strong>AC/DC Hipot, Insulation Resistance (IR), Ground Bond, Continuity, and built-in switching.<br><strong>High Performance: </strong>5KV AC/DC Hipot, leakage current measurement to 100 nano-amps, IR to 450GΩ, and Ground Bond to 30 amps.<br><strong>Safety and Reliability: </strong>Designed and built in the USA with a fan-free design for quiet operation and high reliability.<br><strong>Versatile Connectivity: </strong>USB, RS232, and Digital I/O interfaces.<br><strong>Extended Warranty: </strong>Two-year parts and labor warranty.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Typical Applications:</h5>



<p class="wp-block-paragraph"><strong>Production Line Testing: </strong>Ideal for ensuring the safety and compliance of electronic devices.<br><strong>Laboratory Use: </strong>High accuracy and reliability for research and development testing.<br><strong>Quality Control: </strong>Essential for verifying the safety of products before they reach the market.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Test Functions:</h5>



<figure class="wp-block-table"><table><tbody><tr><td><strong>Function</strong></td><td class="has-text-align-center" data-align="center"><strong>V70</strong></td><td class="has-text-align-center" data-align="center"><strong>V71</strong></td><td class="has-text-align-center" data-align="center"><strong>V73</strong></td><td class="has-text-align-center" data-align="center"><strong>V74</strong></td><td class="has-text-align-center" data-align="center"><strong>V76</strong></td><td class="has-text-align-center" data-align="center"><strong>V79</strong></td></tr><tr><td>AC Hipot</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center"></td></tr><tr><td>DC Hipot</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center"></td></tr><tr><td>IR</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center"></td></tr><tr><td>Ground Bond</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center">•</td></tr><tr><td>Low Resistance</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center">•</td></tr><tr><td>16 Ch HV Scanner</td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center"></td><td class="has-text-align-center" data-align="center">•</td><td class="has-text-align-center" data-align="center"></td></tr></tbody></table></figure>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Ordering Information:</h5>



<p class="wp-block-paragraph"><strong>V70: </strong>AC Hipot Tester<br><strong>V71: </strong>AC/DC Hipot Tester<br><strong>V73: </strong>AC/DC/IR Hipot Tester<br><strong>V74: </strong>AC/DC/IR/GB Hipot Tester<br><strong>V76: </strong>AC/DC/IR Hipot Tester with Built-in Scanner<br><strong>V79: </strong>Ground Bond Tester<br><strong>V7X-230V: </strong>Factory Set for 230V Line<br><strong>QT Pro 7: </strong>QuickTest Software<br><strong>TL-115-1: </strong>115V Receptacle Hipot Test Adaptor<br><strong>TL-115-2: </strong>115V Receptacle Hipot &amp; GB Test Adaptor<br><strong>TL-209: </strong>Additional HV/Continuity Test Lead set<br><strong>K-2R: </strong>Additional Ground Bond Lead Set<br><strong>HVW-7: </strong>High Voltage Warning Light<br><strong>RSS-7: </strong>Remote Start Switch<br><strong>RSF-7: </strong>Remote Start Footswitch<br><strong>TL-TP1: </strong>High Voltage Test Pistol<br><strong>HC-V7X: </strong>Hard Carrying Case with Die Cut Foam</p><p>The post <a href="https://westek.com.au/vitrek-v7x-series-hipot-testers/">Vitrek V7X Series Hipot Testers</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
