<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Cell Testers - Westek Electronics</title>
	<atom:link href="https://westek.com.au/category/products/parent-testing-and-measurement-equipment/child-testing-and-measurement-equipment-cell-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://westek.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 09 Feb 2025 01:00:45 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://westek.com.au/wp-content/uploads/2026/05/cropped-Westek-Favicon-32x32.webp</url>
	<title>Cell Testers - Westek Electronics</title>
	<link>https://westek.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MRS-HR: Cell Test System for very high Currents</title>
		<link>https://westek.com.au/mrs-hr-cell-test-system-for-very-high-currents/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 09 Feb 2025 01:00:45 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Cell Testers]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=2096</guid>

					<description><![CDATA[<h4>MRS-HR: Cell Test System for Very High Currents</h4>
<p>The MRS-HR series is a robust and highly efficient cell test system designed for applications requiring very high current levels, accommodating up to 1000A per channel and reaching up to 2400A in parallel mode. The system’s switched-mode amplifier design ensures low heat generation, high efficiency, and a compact form factor, making it ideal for large cell testing and module testing up to 80V.</p>
<p>The post <a href="https://westek.com.au/mrs-hr-cell-test-system-for-very-high-currents/">MRS-HR: Cell Test System for very high Currents</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features:</h5>



<p class="wp-block-paragraph"><strong>Voltage Variants: </strong>Available in 6V and 80V variants, catering to different testing requirements.<br><strong>Current Capabilities: </strong>Handles up to 1000A per channel and up to 2400A in parallel operation.<br><strong>Power Output: </strong>Supports up to 14kW per channel, with energy recovery options increasing efficiency.<br><strong>Efficiency: </strong>High energy efficiency with up to 90% charge efficiency and up to 87% discharge efficiency.<br><strong>Advanced Measurement: </strong>4-wire measurement for enhanced accuracy, with current accuracy up to 0.05%FS.<br><strong>Dynamic Range: </strong>Optional additional current ranges with automatic range switching.<br><strong>Cooling: </strong>Air-cooled with temperature-regulated fans, ensuring stable operation even under heavy loads.<br><strong>Control Modes: </strong>Supports various control modes, including current, voltage, power, and resistance, with combinations available.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Applications:</h5>



<p class="wp-block-paragraph">The MRS-HR series is tailored for demanding applications that involve:<br><strong>Large Cell Testing: </strong>Ideal for testing large battery cells, particularly those requiring high current loads.<br><strong>Module Testing: </strong>Suitable for battery module testing up to 80V, making it versatile for different battery technologies.<br><strong>High-Power Applications: </strong>Supports testing in high-power environments with significant energy recovery capabilities.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Technical Data:</h5>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td><strong>Parameter</strong></td><td><strong>MRS-HR 80V Variant</strong></td><td><strong>MRS-HR 6V Variant</strong></td></tr><tr><td><strong>Charge Voltage</strong></td><td>3-80V</td><td>0-6V</td></tr><tr><td><strong>Discharge Voltage</strong></td><td>3-80V</td><td>1-6V</td></tr><tr><td><strong>Voltage Accuracy / Resolution</strong></td><td>16mV / 24Bit</td><td>1mV / 24Bit</td></tr><tr><td><strong>Channel Configurations</strong></td><td>70A / 1.5kW to 570A / 14kW</td><td>100A to 1000A</td></tr><tr><td><strong>Efficiency (Charge/Discharge)</strong></td><td>Up to 90% / Up to 87%</td><td>Up to 80% / Up to 70%</td></tr><tr><td><strong>Current Accuracy / Resolution / Ripple</strong></td><td>0.05%FS / 24Bit / &lt;0.3% FS</td><td>0.05%FS / 24Bit / &lt;0.3% FS</td></tr><tr><td><strong>Time Resolution / Current Rise Time</strong></td><td>1 µs / &lt; 1ms</td><td>1 µs / &lt; 1ms</td></tr><tr><td><strong>Parallel Operation</strong></td><td>Yes, up to 4 channels</td><td>Yes, up to 4 channels</td></tr><tr><td><strong>Current Ranges</strong></td><td>Optional, up to 3, automatic range switching</td><td>Optional, up to 3, automatic range switching</td></tr><tr><td><strong>Standard Inputs</strong></td><td>Voltage, Current, 2* Pt100/4W, NTC</td><td>Voltage, Current, 2* Pt100/4W, NTC</td></tr><tr><td><strong>Control Modes</strong></td><td>Current, voltage, power, resistance, and combinations</td><td>Current, voltage, power, resistance, and combinations</td></tr><tr><td><strong>Cooling</strong></td><td>Air-cooled, temperature regulated fans</td><td>Air-cooled, temperature regulated fans</td></tr><tr><td><strong>Power Supply</strong></td><td>400V / 3 phases, N, GND, power factor &gt;0.99</td><td>400V / 3 phases, N, GND, power factor &gt;0.99</td></tr><tr><td><strong>Noise</strong></td><td>50 – 80 dB(A)</td><td>50 – 80 dB(A)</td></tr><tr><td><strong>Other Options</strong></td><td>CAN interface, BSD (Battery Safety Device), CMU cell voltage inputs, SSMS interface, Digital-IO or relay outputs</td><td>CAN interface, BSD (Battery Safety Device), CMU cell voltage inputs, SSMS interface, Digital-IO or relay outputs</td></tr><tr><td><strong>Software</strong></td><td>BaSyTest</td><td>BaSyTest</td></tr><tr><td><strong>Interface</strong></td><td>Ethernet</td><td>Ethernet</td></tr></tbody></table></figure>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<p class="wp-block-paragraph">The MRS-HR test systems offer modularity, flexibility, and user-friendly operation, making them an excellent choice for professionals requiring high-current and high-power testing capabilities.</p><p>The post <a href="https://westek.com.au/mrs-hr-cell-test-system-for-very-high-currents/">MRS-HR: Cell Test System for very high Currents</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPS-HR: Test Systems with small to medium power</title>
		<link>https://westek.com.au/lps-hr-test-systems-with-small-to-medium-power/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 09 Feb 2025 00:56:41 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Cell Testers]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=2093</guid>

					<description><![CDATA[<h4>LPS-HR: Test Systems for Small to Medium Power Applications</h4>
<p>The LPS-HR series is designed for testing applications that require small to medium power, with advanced features that make it a versatile choice for various battery testing scenarios. The LPS-HR series is an upgrade over the previous MDS, GSM, and LPS series, offering 24-bit resolution and additional options like parallel operation and a second current range. It is suitable for applications that require precise current control and high voltage testing, with configurable current ranges from 100 microamperes to 60 amperes and voltage capabilities up to 70V. The system supports a maximum power output of 600W per channel.</p>
<p>The post <a href="https://westek.com.au/lps-hr-test-systems-with-small-to-medium-power/">LPS-HR: Test Systems with small to medium power</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features:</h5>



<p class="wp-block-paragraph"><strong>Voltage Range: </strong>2-10V, 12-70V<br><strong>Current Range: </strong>100µA &#8211; 8A, 10A-60A, 100µA-800mA, 1A-8A, 10A-60A.<br><strong>Maximum Power: </strong>600W per channel<br><strong>Resolution and Accuracy: </strong>24-bit resolution, 0.05% accuracy<br><strong>Parallel Operation: </strong>Supports parallel operation with up to 4 channels<br><strong>Dynamic Range Switching: </strong>Automatic dynamic range switching for enhanced precision<br><strong>Energy Recovery: </strong>Optional energy recovery to the grid<br><strong>Temperature Inputs: </strong>NTC temperature input per channel<br><strong>Software: </strong>Controlled by the powerful BaSyTest software with Open Software Interface (OSI) and Remote Control Interface (RCI)<br><strong>Datalogger: </strong>Optional, can be combined with the BaSyTec CMU datalogger, supporting up to 480 inputs per logger and up to 10 loggers per installation.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Applications:</h5>



<p class="wp-block-paragraph">The LPS-HR series is ideal for small to medium power battery testing applications, including:<br><strong>Battery Formation: </strong>Suitable for the formation process of small and medium-sized batteries.<br><strong>Cycle Life Testing: </strong>Precise control and monitoring for battery cycle life tests.<br><strong>Research &amp; Development: </strong>Supports advanced testing protocols for R&amp;D purposes.<br><strong>Quality Control: </strong>Ensures batteries meet required standards and specifications.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<p class="wp-block-paragraph">The LPS-HR test systems provide a high level of flexibility, precision, and reliability, making them an excellent choice for professionals engaged in battery testing and development.</p><p>The post <a href="https://westek.com.au/lps-hr-test-systems-with-small-to-medium-power/">LPS-HR: Test Systems with small to medium power</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>XCTS: Extended Cell Test System</title>
		<link>https://westek.com.au/xcts-extended-cell-test-system/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 09 Feb 2025 00:53:05 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Cell Testers]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=2089</guid>

					<description><![CDATA[<h4>XCTS Mk II: Extended Cell Test System</h4>
<p>The XCTS Mk II series is designed for single-cell testing with voltages up to 6V and currents ranging from 40A to 80A. The system's amplifiers utilize switched technology, resulting in low heat generation, compact design, and high energy efficiency. When operated in parallel mode (optional), the system can handle currents up to 800A. The XCTS Mk II features automatic dynamic current range switching, making it a versatile and precise tool for battery testing.</p>
<p>The post <a href="https://westek.com.au/xcts-extended-cell-test-system/">XCTS: Extended Cell Test System</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features:</h5>



<p class="wp-block-paragraph"><strong>Voltage Range: </strong>1-6V<br><strong>Current Range: </strong>40A, 60A, 80A (800A in parallel mode)<br><strong>Precision: </strong>Up to 1mA with automatic dynamic range switching<br><strong>Energy Recovery:</strong> Optional to the grid for enhanced efficiency<br><strong>Control Software:</strong> BaSyTest Battery Test Software</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Applications:</h5>



<p class="wp-block-paragraph"><strong>Battery Testing:</strong> Ideal for testing and formation of single-cell batteries in research and production environments.<br><strong>High-Power Cell Testing: </strong>Suitable for testing cells in high-current applications like electric vehicles, power tools, and energy storage systems.<br><strong>Energy Efficiency: </strong>The optional energy recovery feature makes the XCTS Mk II particularly well-suited for applications focused on sustainable energy solutions.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Advantages:</h5>



<p class="wp-block-paragraph"><strong>High Precision: </strong>Achieve up to 1mA precision with automatic and dynamic current range switching.<br><strong>Compact Design: </strong>The small 19” form factor ensures the system fits easily into any lab or production environment.<br><strong>Scalability: </strong>The system can be expanded with parallel operation, reaching up to 800A for high-current applications.<br><strong>Energy Recovery: </strong>Optional grid recovery for efficient energy use and reduced operational costs.<br>User-Friendly Software: BaSyTest software provides a powerful and intuitive interface for test management.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Technical Data</h5>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td><strong>Specification</strong></td><td><strong>XCTS Mk II 40A</strong></td><td><strong>XCTS Mk II 60A</strong></td><td><strong>XCTS Mk II 80A</strong></td></tr><tr><td><strong>Max. Current per Channel</strong></td><td>40A</td><td>60A</td><td>80A</td></tr><tr><td><strong>Max. Power per Channel</strong></td><td>200W</td><td>300W</td><td>400W</td></tr><tr><td><strong>Parallel Operation</strong></td><td>Yes, up to 80A</td><td>Optional, up to 600A</td><td>Optional, up to 800A</td></tr><tr><td><strong>Range Switching</strong></td><td>Automatic and dynamic</td><td>Automatic and dynamic</td><td>Automatic and dynamic</td></tr><tr><td><strong>Channels per Unit</strong></td><td>8 or 20</td><td>5, 10, or 12</td><td>4 or 10</td></tr><tr><td><strong>Voltage Range</strong></td><td>0-6V</td><td>0-6V</td><td>0-6V</td></tr><tr><td><strong>Min. Discharge Voltage</strong></td><td>1V</td><td>1V</td><td>1V</td></tr><tr><td><strong>Resolution</strong></td><td>0.1mV / 1mA</td><td>0.1mV / 0.05mA</td><td>0.1mV / 1mA</td></tr><tr><td><strong>Accuracy</strong></td><td>1mV / 10mA + 0.1% up to 20A</td><td>1mV / 10mA + 0.1% up to 40A</td><td>1mV / 10mA + 0.1% up to 80A</td></tr><tr><td></td><td>20mA + 0.1% up to 40A</td><td>30mA + 0.1% up to 60A</td><td>40mA + 0.1% up to 80A</td></tr><tr><td><strong>Measurement</strong></td><td>Voltage (4W), current, temperature</td><td>Voltage (4W), current, temperature</td><td>Voltage (4W), current, temperature</td></tr><tr><td><strong>Temperature Input</strong></td><td>NTC 5k (Epcos B57861S0502) or GE TK95</td><td>NTC 5k (Epcos B57861S0502) or GE TK95</td><td>NTC 5k (Epcos B57861S0502) or GE TK95</td></tr><tr><td><strong>Time Resolution / Rise Time</strong></td><td>1µs / 1ms</td><td>1µs / 1ms</td><td>1µs / 1ms</td></tr><tr><td><strong>Sampling Rate</strong></td><td>Peak 0.5ms / Min. 10ms</td><td>Peak 0.5ms / Min. 10ms</td><td>Peak 0.5ms / Min. 10ms</td></tr><tr><td><strong>Current/Voltage Ripple</strong></td><td>&lt; 0.01% FS / &lt; 0.5mV</td><td>&lt; 0.01% FS / &lt; 0.5mV</td><td>&lt; 0.01% FS / &lt; 0.5mV</td></tr><tr><td><strong>Control Mode</strong></td><td>Current, voltage, power, resistance, and combinations</td><td>Current, voltage, power, resistance, and combinations</td><td>Current, voltage, power, resistance, and combinations</td></tr><tr><td><strong>Energy Recovery</strong></td><td>Yes, between channels</td><td>Yes, between channels</td><td>Yes, between channels</td></tr><tr><td><strong>Recovery to the Grid</strong></td><td>Optional, total efficiency up to 70% (charge) / 60% (discharge)</td><td>Optional, total efficiency up to 70% (charge) / 60% (discharge)</td><td>Optional, total efficiency up to 70% (charge) / 60% (discharge)</td></tr><tr><td><strong>Software</strong></td><td>BaSyTest</td><td>BaSyTest</td><td>BaSyTest</td></tr><tr><td><strong>Interface</strong></td><td>Ethernet</td><td>Ethernet</td><td>Ethernet</td></tr><tr><td><strong>Connector</strong></td><td>D-SUB 7W2</td><td>D-SUB 9W4</td><td>D-SUB 9W4</td></tr><tr><td><strong>Noise</strong></td><td>70 &#8211; 85dB(A) (without recovery to the grid)</td><td>60 &#8211; 83dB(A) (with recovery to the grid)</td><td>60 &#8211; 83dB(A) (with recovery to the grid)</td></tr><tr><td><strong>Size/Weight (No Recovery)</strong></td><td>450mm x 310mm x 500mm / 40kg</td><td>450mm x 310mm x 500mm / 40kg</td><td>450mm x 310mm x 500mm / 40kg</td></tr><tr><td><strong>Power Supply</strong></td><td>400VAC / 50Hz / 3 phases + N</td><td>400VAC / 50Hz / 3 phases + N</td><td>400VAC / 50Hz / 3 phases + N</td></tr><tr><td><strong>Size/Weight (With Recovery)</strong></td><td>450mm x 310mm x 620mm / 70kg</td><td>450mm x 310mm x 620mm / 70kg</td><td>450mm x 310mm x 620mm / 70kg</td></tr><tr><td><strong>Power Supply (With Recovery)</strong></td><td>400VAC / 50Hz / 3 phases + N</td><td>400VAC / 50Hz / 3 phases + N</td><td>400VAC / 50Hz / 3 phases + N</td></tr></tbody></table></figure>



<p class="wp-block-paragraph"></p><p>The post <a href="https://westek.com.au/xcts-extended-cell-test-system/">XCTS: Extended Cell Test System</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cell Test System (CTS)</title>
		<link>https://westek.com.au/cell-test-system-cts/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 09 Feb 2025 00:48:57 +0000</pubDate>
				<category><![CDATA[All Products]]></category>
		<category><![CDATA[Cell Testers]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://westek.com.au/?p=2086</guid>

					<description><![CDATA[<h4>BaSyTec CTS Battery Test System</h4>
<p>The BaSyTec CTS Battery Test System is designed for precise and efficient testing of small cells, including material probes in 3-electrode configurations and mid-size cells up to 20A. The system’s compact design enables it to be used as a tabletop unit with up to 32 independent test channels, each equipped with a temperature input for the cell. The system’s advanced features include automatic dynamic range switching, providing up to 200nA precision at low current levels.</p>
<p>The post <a href="https://westek.com.au/cell-test-system-cts/">Cell Test System (CTS)</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features</h5>



<p class="wp-block-paragraph"><strong>Voltage Range: </strong>1-6V or ±6V<br><strong>Current Range: </strong>Up to 5A (20A in parallel operation)<br><strong>Precision: </strong>Up to 200nA current accuracy<br><strong>Optional Input: </strong>Reference electrode input available<br><strong>Automatic Dynamic Switching: </strong>4 current ranges with seamless switching, ensuring a relative accuracy of at least 0.33% across the range from 60μA to 20A<br><strong>Software Control: </strong>Managed by the powerful and user-friendly BaSyTest Software</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Technical Specifications</h5>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td><strong>Parameter</strong></td><td><strong>CTS Standard</strong></td><td><strong>CTS LAB</strong></td><td><strong>CTS LAB XL</strong></td></tr><tr><td><strong>Channels per Unit</strong></td><td>Up to 32</td><td>Up to 32</td><td>20</td></tr><tr><td><strong>Voltage Range</strong></td><td>0-6V</td><td>±6V</td><td>±6V</td></tr><tr><td><strong>4-Wire Measurement</strong></td><td>Yes</td><td>Yes</td><td>Yes</td></tr><tr><td><strong>Minimum Discharge Voltage</strong></td><td>200mV or 0.2Ω*current (whichever is greater)</td><td>-6V</td><td>-6V</td></tr><tr><td><strong>Current Ranges</strong></td><td>5A/300mA/15mA/1mA</td><td>3A/250mA/15mA/1mA</td><td>5A/300mA/15mA/1mA</td></tr><tr><td><strong>Current Accuracy</strong></td><td>1mA/50μA/2.5μA/0.2μA</td><td>1mA/50μA/2.5μA/0.2μA</td><td>1mA/50μA/2.5μA/0.2μA</td></tr><tr><td><strong>Voltage Accuracy</strong></td><td>1mV</td><td>1mV</td><td>1mV</td></tr><tr><td><strong>Resolution</strong></td><td>16Bit / 1μs</td><td>16Bit / 1μs</td><td>16Bit / 1μs</td></tr><tr><td><strong>Parallel Operation</strong></td><td>Yes, up to 4 channels</td><td>Yes, up to 4 channels</td><td>Yes, up to 4 channels</td></tr><tr><td><strong>Additional Inputs</strong></td><td>NTC temperature input (Epcos B57861S0502)</td><td>NTC temperature input (Epcos B57861S0502)</td><td>NTC temperature input (Epcos B57861S0502)</td></tr><tr><td><strong>Optional Reference Voltage</strong></td><td>±6V, 1mV accuracy, leakage &lt; 50nA, 200ms sample rate</td><td>±6V, 1mV accuracy, leakage &lt; 50nA, 200ms sample rate</td><td>±6V, 1mV accuracy, leakage &lt; 50nA, 200ms sample rate</td></tr><tr><td><strong>Digital I/O</strong></td><td>Optional, TTL-like, 3 per channel, not isolated</td><td>Optional, TTL-like, 3 per channel, not isolated</td><td>Optional, TTL-like, 3 per channel, not isolated</td></tr><tr><td><strong>Sampling Rate</strong></td><td>Peak 0.5ms, Min. 10ms but not more than 1kHz continually per system</td><td>Peak 0.5ms, Min. 10ms but not more than 1kHz continually per system</td><td>Peak 0.5ms, Min. 10ms but not more than 1kHz continually per system</td></tr><tr><td><strong>Current Rise Time</strong></td><td>&lt; 50μs</td><td>&lt; 50μs</td><td>&lt; 50μs</td></tr><tr><td><strong>3-Electrode Configurations</strong></td><td>Limited</td><td>Yes</td><td>Yes</td></tr><tr><td><strong>Control Modes</strong></td><td>Current, voltage, power, resistance, and combinations</td><td>Current, voltage, power, resistance, and combinations</td><td>Current, voltage, power, resistance, and combinations</td></tr><tr><td><strong>Other Methods</strong></td><td>Cyclic voltammetry, GITT</td><td>Cyclic voltammetry, GITT</td><td>Cyclic voltammetry, GITT</td></tr><tr><td><strong>Software</strong></td><td>BaSyTest</td><td>BaSyTest</td><td>BaSyTest</td></tr><tr><td><strong>Interface</strong></td><td>Ethernet</td><td>Ethernet</td><td>Ethernet</td></tr><tr><td><strong>Battery Connectors</strong></td><td>D-SUB 9-pin</td><td>D-SUB 9-pin</td><td>D-SUB 9-pin</td></tr><tr><td><strong>Holders for Cylindric Cells</strong></td><td>Available</td><td>Available</td><td>Available</td></tr><tr><td><strong>Size per Unit (Max.)</strong></td><td>19” system 6HE units, 450x280x550mm</td><td>19” system 6HE units, 450x280x550mm</td><td>19” system 6HE units, 450x280x550mm</td></tr><tr><td><strong>Weight per Unit (Max.)</strong></td><td>28kg (32 channels)</td><td>28kg (32 channels)</td><td>28kg (32 channels)</td></tr><tr><td><strong>Noise Level</strong></td><td>&lt; 55dB(A)</td><td>&lt; 55dB(A)</td><td>&lt; 55dB(A)</td></tr><tr><td><strong>Input Power / Voltage Range</strong></td><td>&lt; 1700W / 110-264VAC / 47-63Hz</td><td>&lt; 1700W / 110-264VAC / 47-63Hz</td><td>&lt; 1700W / 110-264VAC / 47-63Hz</td></tr><tr><td><strong>Max. Input Current per Unit</strong></td><td>&lt; 16A @ 110V, &lt; 8A @ 220V</td><td>&lt; 16A @ 110V, &lt; 8A @ 220V</td><td>&lt; 16A @ 110V, &lt; 8A @ 220V</td></tr></tbody></table></figure>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Applications</h5>



<p class="wp-block-paragraph">Ideal for single-cell testing of small to mid-size cells.<br>Suitable for material probe testing in 3-electrode configurations.<br>Can be used for cyclic voltammetry, GITT, and other advanced battery testing methods.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<p class="wp-block-paragraph">The BaSyTec CTS Battery Test System is a versatile and precise solution for researchers and engineers working with small to mid-size cells. Its modular and user-friendly design, combined with the powerful BaSyTest software, makes it an industry reference for battery testing.</p><p>The post <a href="https://westek.com.au/cell-test-system-cts/">Cell Test System (CTS)</a> first appeared on <a href="https://westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>