Near-Field Microprobe Sets ICR HV H Field
The ICR HV set contains one ICR near-field microprobe for magnetic field measurement. The measuring coil is vertical in the probe head. The ICR probes are operated with a positioning system (Langer Scanner).

The ICR HV set contains one ICR near-field microprobe for magnetic field measurement. The measuring coil is vertical in the probe head. The ICR probes are operated with a positioning system (Langer Scanner).

The ICR HH set contains one ICR near-field microprobe for magnetic field measurement. The measuring coil is horizontal in the probe head. The ICR probes are operated with a positioning system (Langer Scanner).

The MFA family consists of four active magnetic field probes. The MFA 01 includes three magnetic field probes. The MFA 02 set consists of two magnetic field probes for low frequency measurements.

The HR family consists of an H-field probe and an E-field probe for the measurement of high-frequency RF fields up to 40 GHz during development.

The SX family consists of three H-field probes and one E-field probe.
The SX1 set (two H-field probes and one E-field probe) and the SX-R 20-1 set are available.

The XF family consists of four magnetic-field probes and three E-field probes. The XF1 set (four magnetic-field probes and one E-field probe) as well as customized sets are available.

The RF family consists of nine magnetic field probes and six E-field probes, which are available in sets. These sets are optimized for different measurement tasks.
We are happy to create customized sets upon request.

The LF family consists of seven magnetic-field probes, four of which are included in our LF1 probe set. We are happy to create customized sets upon request.

FS-SET 7100 B Nearfield Probe Set including:• HFSL 7101 B Active Near Field Probe (magnetic), 9 kHz – 30 MHz• HFSH 7102 B Active Near Field Probe (magnetic), 4 MHz

FSH3D Isotropic H-Field Antenna for the Rohde und Schwarz handheld spectrum analyser FSH or the TS-EMF System. • 9 kHz – 200 (300) MHz• Light weight low attenuation radom• Outer

The Coupling- / Decoupling Networks are used to inject common mode disturbances to Equipment under Test (EuT). Further the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

MagTest System System to test the immunity against magnetic fields acc. MIL-461 E, ISO 11452-8, EN 61000-4-8, SAE J551-17 etc. The system components will be individually configured for your requirements.