Schloder EMV Pulse Generator
PG 01-2000 The pulse generator PG 01 – 2000 is suitable for insulation testing and testing the surge voltage strength of electrical and electronic electricity meters. When idle, the generator

PG 01-2000 The pulse generator PG 01 – 2000 is suitable for insulation testing and testing the surge voltage strength of electrical and electronic electricity meters. When idle, the generator

IGUU 2918 Calibration-Pulse Generatoracc. CISPR 16for Band A, B, C, D(9 kHz-1000 MHz)To calibrate the pulseresponse of EMI receivers.Pulse repetition frequency main generator 0.1 – 200 Hz (aux. generator up

SY 9223-439 The SY 9223-439 transformer causes a voltage transformation Uin / Uout = 1 / 2 and is designed for operation with hand- held field coil – e.g. FESP

BBV 9743 B – Broadband Preamplifier Frequency range (nominel): 10 MHz – 6 GHz Noise figure: typ. <2.7 dB (1.0 GHz) Gain: typ. +28 dB Amplitude flatness: < ± 3

PA 2522 set Preamplifier 10 MHz up to 22 GHz The PA 2522 preamplifier was designed for the amplification of measuring signals, e.g. weak signals of near-field probes with high resolution.

To ensure electronic and electrical devices withstand electrostatic discharges, ESD simulators are used to generate these discharges artificially and examine their effects on the devices. These tests, which evaluate the protective measures, are governed by standards such as IEC 61000-4-2 and ISO 10605.

The CAN and LIN bus systems allow for floating signal transmission according to the CAN/LIN standard.

Langer EMV-Technik GmbH`s optical signal transmission systems are used for the floating transmission of signals from the device under test up to a distance of 20 m.

Langer EMV-Technik GmbH`s optical signal transmission systems are used for the floating transmission of signals from the device under test up to a distance of 20 m.

The measurement technology for the development stage enables the detection of magnetic and electric field sources at your PCB directly at the workplace.

The near-field microprobe is designed for a high-resolution measurement of electrical near fields. With the ICR E probe the following measurements can be performed:
• Surface Scan via IC according to IEC 61967-3
• Volumenscan via IC
• Pin Scan

The ICR 03 set contains three of our ICR near-field microprobes (magnetic or E field) of your choice.
The probes are used to measure magnetic or electric near fields with extremely high resolution and sensitivity. Optimal is a distance of < 1 mm to the measuring object. The probe head is equipped with either a vertical (HV) or horizontal (HH) measuring coil.
A preamplifier is integrated in every probe, which is powered by the BT 706 bias tee.