Key Features:
Robust Design: Engineered for superior filtering of power line disturbances, ensuring long-term reliability and durability.
No Derating Required: Harmonic compensated and protected to assure optimal performance in the presence of harmonics.
Wide Range of Impedance Options: Available in 1.5%, 3%, and 5% impedance levels to meet various application needs.
Comprehensive Current Range: Supports a full line of currents from 1A to 1,500A.
Continuous Service Factor: Reactors rated from 1 to 750 Amps are designed with a 150% continuous service factor, while those rated above 750 Amps have a 125% continuous service factor.
High Overload Rating: Capable of handling 200% of the rated current for 30 minutes and 300% of the rated current for 1 minute.
Noise Reduction: Constructed to significantly reduce audible noise, enhancing the working environment.
Multiple Cabinet Designs: Available in configurations that meet NEMA 1/2 and 3R standards, providing flexibility in installation.
Benefits:
Enhanced Power Quality: Delivers improved power quality by effectively reducing harmonic distortion and power line disturbances.
Increased Productivity: Reduces nuisance tripping and equipment shutdowns, leading to more consistent and reliable operations.
Complete Peace of Mind: Robust construction and high performance provide reliability and confidence in the system’s operation.
Versatile Application: Suitable for virtually any 4 or 6-pulse rectifier or power conversion unit, ensuring broad applicability.
Specifications:
Impedance Levels: 1.5%, 3%, and 5%
Continuous Service Factor:
• Reactors rated 1 to 750 Amps – 150% of rating
• Reactors rated above 750 Amps – 125% of rating
Overload Rating:
• 200% of rated current for 30 minutes
• 300% of rated current for 1 minute
Input Voltage Range: 208V – 690V
Current Range: 1A – 1,500A
Typical Applications:
Variable Frequency Drives (VFDs): Ensures the reliable and efficient operation of VFDs by mitigating power line disturbances.
Sensitive Equipment: Protects sensitive equipment from power quality issues that can cause damage or shutdowns.
4 or 6-Pulse Rectifiers: Provides robust filtering solutions for rectifiers, enhancing their performance and longevity.
Power Conversion Units: Suitable for a variety of power conversion applications, ensuring stable and efficient operation.
Why Choose MTE RL Line/Load Reactors?
Choosing MTE RL Line/Load Reactors means investing in a reliable and proven solution for power quality. With their robust design, high overload capacity, and wide range of applications, these reactors ensure that your equipment runs smoothly and efficiently, minimizing downtime and maintenance costs. Enhance your power quality, boost productivity, and achieve peace of mind with MTE’s RL Line/Load Reactors.
Line/Load Selection Table – 1/.75-10/7.5 HP/kw
208-690 Volts, 50/60 hz (Open Type)
Ratings | HP/kw | 1/.75 | 1.5/1.1 | 2/1.5 | 3/2.2 | 5/3.7 | 7.5/5.5 | 10/7.5 |
400 Volts | 3% Impedance | RL-00403 | RL-00402 | RL-00402 | RL-00803 | RL-00802 | RL-01202 | RL-01802 |
50/60 HZ | ||||||||
400 Volts | 5% Impedance | RL-00202 | RL-00404 | RL-00403 | RL-00804 | RL-00803 | RL-01203 | RL-01803 |
50/60 HZ | ||||||||
690 Volts | 2% Impedance | RL-00403 | RL-00402 | RL-00801 | RL-01202 | |||
50/60 HZ | ||||||||
690 Volts | 3% Impedance | RL-00402 | RL-00404 | RL-00804 | RL-01203 | |||
50/60 HZ |
Line/Load Selection Table – 15/11-100/75 HP/kw
208-690 Volts, 50/60 hz (Open Type)
Ratings | HP/kw | 15/11 | 20/15 | 25/18.5 | 30/22 | 40/30 | 50/37.5 | 60/45 | 75/55 | 100/75 |
400 Volts 50/60 HZ | 3% Impedance | RL-2502 | RL-3502 | RL-4502 | RL-4502 | RL-8002 | RL-8002 | RL-10002 | RL-13002 | RL-16002 |
400 Volts 50/60 HZ | 5% Impedance | RL-2503 | RL-3503 | RL-4503 | RL-5503 | RL-8003 | RL-10003 | RL-10003 | RL-13003 | RL-16003 |
690 Volts 50/60 HZ | 2% Impedance | RL-1202 | RL-1802 | RL-2502 | RL-2502 | RL-3502 | RL-4502 | RL-5502 | RL-5502 | RL-8002 |
690 Volts 50/60 HZ | 3% Impedance | RL-1203 | RL-1803 | RL-2503 | RL-2503 | RL-3503 | RL-4503 | RL-4502 | RL-5503 | RL-8003 |
Line/Load Selection Table – 125/93 750/550 HP/kw
208-690 Volts, 50/60 hz (Open Type)
Ratings | HP/kw | 125/93 | 150/112 | 200/150 | 250/187 | 300/225 | 350/262 | 400/300 | 500/375 | 600/450 | 700/550 |
480 Volts 50/60 HZ | 3% Impedance | RL-16002 | RL-20002B14 | RL-25002B14 | RL-32002B14 | RL-40002B14 | RL-50002 | RL-50002 | RL-60002 | RL-75002 | RL-85002B14 |
480 Volts 50/60 HZ | 5% Impedance | RL-16003 | RL-20003B14 | RL-25003B14 | RL-32003B14 | RL-40003B14 | RL-50003 | RL-50003 | RL-60003 | RL-75003 | RL-85003B14 |
690 Volts 50/60 HZ | 2% Impedance | RL-10002 | RL-13002 | RL-16002 | RL-20002B14 | RL-25002B14 | RL-25002B14 | RL-32002B14 | RL-40002B14 | RL-40002B14 | RL-50002 |
690 Volts 50/60 HZ | 3% Impedance | RL-10003 | RL-13003 | RL-16003 | RL-20003B14 | 25003B14 | RL-25003B14 | RL-32003B14 | RL-40003B14 | RL-50003 | RL-50003 |