Features:
Voltage Range: 30V / 305Vrms (AC); 40V / 400Vdc
Current Range: 0.02 / 0.2 / 2 / 20 Arms (AC), 200 Arms (Inrush); 0.02 / 0.2 / 2 / 20 Adc (DC), 200 Adc (Inrush)
Power Measurement: Measures AC/DC voltage, current, power, power factor, and frequency. Also provides inrush current measurement.
Measurement Frequency: DC, 40~70Hz
4-Channel Design: The power meter is available in 1 to 4 channels, allowing simultaneous measurement of multiple units under test (UUT).
Programmable Update Rate: The meter’s update rate can be adjusted for different testing scenarios.
Inrush Current Measurement: Programmable inrush delay (0-99.9ms) and period (0.1-99.9s) for accurate inrush current testing.
Low-Pass Filter: A built-in 50kHz low-pass filter eliminates high-frequency interference to ensure precise measurement.
Applications:
The 4013A Power Meter is ideal for testing AC/DC adapters, chargers, LED drivers, UPS systems, regulators, inverters, batteries, and DC/DC converters. It supports measurement of voltage, current, power, and efficiency for applications involving both AC and DC power supplies.
Technical Specifications:
AC Voltage: 30V / 305Vrms, 16-bit resolution, ±0.5% accuracy
DC Voltage: 40V / 400V, ±0.5% accuracy
AC Current: 20mA / 200mA / 2A / 20A / 200A (Inrush), ±0.5% accuracy
DC Current: 20mA / 200mA / 2A / 20A / 200A (Inrush), ±0.5% accuracy
Power Measurement: 0.6W to 6000W (AC/DC), 32-bit resolution, ±0.5% accuracy
Power Factor: 0.01 resolution, accurate to 1%
Frequency: 40~70Hz, ±0.1Hz accuracy
Structure and Configuration:
The 4013A integrates 12-bit A/D converters in each channel, sampling and converting voltage and current signals. These signals are processed by a 16-bit high-speed processor and the data is communicated via RS-232 interface. The power meter can be configured for various ATE setups, including systems with AC sources like the 5302A and 5303 AVR for inrush current testing.
Optional Configurations:
Can be integrated with the 6010 ATE for testing AC/DC adapters and chargers.
Compatible with 5302A 270VA AC Source, 5310 1KVA AC Source, and 5303 3KVA AVR for power parameter measurements and efficiency tests.
Supports simultaneous testing of up to 4 UUTs using 1-4 AC sources in conjunction with the 4013A Power Meter.