Schwarzbeck Voltage Probes

Schwarzbeck Voltage Probes

In addition to EMI measurement with LISNs (Line Impedance Stabilisation Networks, Artificial Mains Networks), Probes are used for Terminal or Line voltage measurement. LISNs are required to feed the Equipment under Test (EuT) with mains power, to reduce external line interference, to offer the EuT a standardized impedance and to route the extracted r.-f. voltage to the EMI receiver.
Voltage Probes

Probes are used for terminal voltage measurement, also on cables, output sockets, PCB traces. In many cases high input impedance and low capacitance is required for this purpose. Active Probes may not be used for general Interference measurement, as pulses could by far exceed the linear voltage range. This not only causes limiting and distortion effects but also intermodulation that changes the frequency distribution of spectral  components.

These resistive dividing probes are perfectly linear and free of these effects.

By the use of an AC and pulse-compatible input blocking capacitor (that is also free of partial discharge effects), EMI measurement is also possible on AC power lines up to 250 V ac or DC sources up to 500 V.
High-Voltage Probes up to 10 kV (20 kV) DC or 2 kV AC with 1500 Ω input || 4 pF input capacity are available as TK  9420.

For the max. power line voltage of 250 V ac two probes are available with input resistances of 1.5 kΩ, and 2.5 kΩ with the model numbers TK 9420, and TK 9417.

TK 9261 – Active Probe

The TK 9261 is an active high-impedance RF voltage probe equipped with an internal impedance transformer which allows using it with 50 Ω measurement devices (such as spectrum and network analyzers or test receivers).

Datasheet

Nominal frequency range (±1 dB): 100 kHz – 100 MHz
Useable frequency range:(±3 dB): 50 kHz – 700 MHz
Input damping resistance: >100 kΩ
Input capacitance: 1.8 pF typ.
Output impedance: 50 Ω
Gain: 0 dB
Maximum output level: 1.4 V peak
Maximum input d.c. level: 500 V
Maximum input a.c. level: 10 Vp-p
Output: N-plug
According to: Renault 36-00-808
Power supply: +12…15 V
 50 mA
DC-connector: 5.5 mm / 2.5 mm
Ambient temperature: -10° … +60°C
Weight: 300 g
TK 9422 – High Power Voltage Probe

Datasheet

Input Impedance: 5 kΩ || 4 pF
Frequency Range: (9) 150 kHz – 30 MHz
Voltage Range: HF: <100 V
 AC 50/60 Hz: < 10 kV
 DC: < 15 kV
Accurency of Voltage Division: 150 kHz – 30 MHz ± 2 dB
Input Impedance of Test Receiver: 50 Ω, SWR ≤ 1.1
Internal Coupling Capacitor: 1.25 nF
Terminals: 4 mm
Ground Connection: insulated litz wire
 Banana plug 4 mm
Coax cable: RG 58, 2 m, BNC
Audio Frequency Impedance: 1.25 nF + 5 kΩ
Max. Power: 30 W
Weight: 400 g
Dimensions: 440 mm x 23 mm ∅
TK 9421 – High Power Voltage Probe

Datasheet

Input Impedance: 1.5 kΩ || 4 pF
Frequency Range: (9) 150 kHz – 30 MHz
Voltage Range: HF: <100 V
 AC 50/60 Hz: < 10 kV
 DC: < 15 kV
Accuracy of Voltage Division: 150 kHz – 30 MHz ± 2 dB
Input Impedance of Test Receiver 50 Ω, SWR ≤ 1.1
Internal Coupling Capacitor: 1.25 nF
Terminals: 4 mm
Ground Connection: insulated litz wire, Banana plug 4 mm
Coax Cable: RG 58, 2 m, BNC
Audio Frequency Impedance: 1.25 nF + 1.5 kΩ
Max. Power: 20 W
Weight: 200 g
Dimensions: 380 mm x 23 mm ∅
TK 9420 – Voltage Probe

Option: Plug-In Divider VT 9420
The divider (option) can be used to determine the approximate RF-Impedance of unknown EuTs according to CISPR 16-2

Datasheet

Input Impedance: 1.5 kΩ || 4 pF
Frequency Range: 9 kHz – 30 MHz
Voltage Range: HF: <30 V
 AC 50/60 Hz: < 2.5 kV
 DC: < 4.4 kV
Freq. Range w. constant Correction of 30 dB: 20 kHz – 30 MHz
Accuracy of Voltage Division: 30 kHz – 30 MHz ± 1 dB
Input Impedance of Test Receiver: 50 Ω, SWR ≤ 1.1
Internal Coupling Capacitor: 10 nF
Terminals: 4 mm
Ground Connection: insulated litz wire, Banana plug 4 mm
Coax Cable: RG 58, 2 m, BNC
Audio Frequency Impedance: 10 nF + 1.5 kΩ
Weight: 180 g
Dimensions: 175 mm x 23 mm ∅
TK 9417 – RF Probe

Datasheet

Nominal Input R: 2.5 kΩ
Frequency Range: 10 kHz – 30 MHz
Series Resistor: 2450 Ω
 0.2 W
Series Capacity: 10 nF 250 VAC
Input Current: 0.79 mA
250 V / 50 Hz
Input Current: 6.25 mA
250 V / 400 Hz
Input Current-|Z| at 10 kHz: 2960 Ω
eff. shunt Capac.: ca. 2 pF